渔光互补场景下光伏组件布置方式对电气性能的影响分析

Analysis of the impact of photovoltaic module layout on electrical performance in the fishery photovoltaic complementary scenario

  • 摘要: 为明确渔光互补场景下光伏组件布置方式对电气性能的影响,以某地区100MW 渔光互补项目为案例,设计了柔性支架模块化布置、横向四排固定支架布置和竖向双排固定支架布置三种方案,采用PVsyst 仿真软件进行全生命周期对比分析。结果表明:横向四排固定支架布置方案年发电量为125.3GW·h,阴影损失率为7.6%,总损耗率为21.8%,各项指标均为最优,实现了发电效率与阴影控制的最佳平衡,为渔光互补项目提供了优化工程解决方案。

     

    Abstract: In order to clarify the impact of photovoltaic module layout on electrical performance in the context of fishery photovoltaic complementary scenarios, this study takes a 100MW fishery photovoltaic complementary project in a certain region as a case study, and designs three schemes: flexible support modular layout, horizontal four row fixed bracket layout, and vertical double row fixed bracket layout. PVsyst simulation software is used for a full life cycle comparative analysis. The results showed that the horizontal four row fixed bracket layout scheme had an annual power generation of 125.3GW·h, a shadow loss rate of 7.6%, and a total loss rate of 21.8%. All indicators were optimal, achieving the best balance between power generation efficiency and shadow control, and providing an optimized engineering solution for the fishery photovoltaic complementary project.

     

/