基于改进强化学习的电网无功电压优化控制研究

Research on reactive power and voltage optimal control of power grid based on improved reinforcement learning

  • 摘要: 针对高比例分布式电源接入下电网无功电压控制难题,提出一种改进强化学习方法,构建多尺度特征融合与 自适应探索机制,建立三级协同控制架构,将优化问题转化为马尔可夫决策过程,设计策略-价值双网络并融入多 约束协同校验。基于IEEE 33节点系统开展仿真验证,结果表明:电压偏移降至2.1%,网损率降到2.13%,收敛 时间缩短至186 s,高渗透率工况下电压越限率低于1.18%,全约束条件下安全运行时长达23.7 h,显著提升系统的 控制精度、实时性与鲁棒性。

     

    Abstract: Aiming at the difficult problems of reactive power and voltage control in power grids with high proportion of distributed generation access, an improved reinforcement learning method is proposed, constructs a multi-scale feature fusion and adaptive exploration mechanism, establishes a three-level cooperative control architecture, transforms the optimization problem into a Markov decision process, designs a strategy-value dual network and integrates multi-constraint cooperative verification. Simulation tests are carried out on the IEEE 33-bus system. The results shows that the voltage deviation is reduced to 2.1%, the network loss rate is 2.13%, the convergence time is shortened to 186 s, the voltage over-limit rate under high permeability conditions is less than 1.18%, and the safe operation duration under full constraints reaches 23.7 h, which significantly improves the control accuracy, real-time performance and robustness.

     

/

返回文章
返回